Ultrasonic Transducer Driver Amplifiers

Summary MD1712 is a two-channel, five-level, high voltage and high speed transmitter driver IC. It is designed for medical ultrasound imaging applications, but can also be used for metal flaw detection, Non-Destructive Testing (NDT), and for driving piezoelectric transducers. The MD1712 is a two-channel logic controller circuit with low impedance MOSFET gate drivers. There are two sets of control logic inputs, one for channel A and one for channel B. Each channel consists of three pairs of MOSFET gate drivers.

PGA460 Ultrasonic Signal Processor and Transducer Driver. Chip ultrasonic transducer driver and signal. Krupenchuk igri so zvukami i bukvami skachatj. Consisting of a low-noise amplifier followed by a. This brief presents a monolithically integrated fully differential linear HV amplifier as the driver of an ultrasonic transducer. The linear amplifier is capable of.

These drivers are designed to match the drive requirements of TC6320. The MD1712 drives six TC6320s. Each pair consists of an N-channel and a P-channel MOSFET. They are designed to have the same impedance and can provide peak currents of over 2.0amps.

Hi MM, I used a 'burst' method of driving 200KHz and 30KHz transducers. The transducer pulse generator was from a square wave osc, tunable over a narrow range in order to get the optimum power out from the transducer. The pulse or burst width generator was adjustable from 100uSec thru 10mSec, this enabled a level of power control in the acoustic pulse.

The transducer driver stage was a NPN power transistor driving a 1:3 or 1:5 transformer at 30KHz or 200KHz respectively, supply voltage 12V or 24V depending upon the required acoustic power. My product applications were for hydro-graphic depth echo sounders, working in water depths of 0.5mtr upto 400mres.

E Is you application bio-diesel.? Hi Eric, Isn't the number of cycles (burst) of 40khz determined by the length of the ON pulse? A 20ms pulse will have more cycles that a 2ms one (10 times more).

Transducer

The size of the Burst is directly related to the duty cycle. In order to increase the burst time, we need an amplifier that will take more power.

Currently I can't get past a duty cycle of 1% without smoking the heatsinked Fet. EG: 5ms ON and 500mx OFF. As I mentioned before, I dip all transducers to find their exact resonant TX frequencies and their band pass. Astrology chart software telugu 2017 Then I program the CPU to change frequency over the band pass. If the BP is say 2khz wide, I will step the frequency up by 100hz every few seconds.

That way I send multiple bursts to 20 different frequency locations, of which a few should be more effective in ringing the wafer. What do you think? I built a cat scarer at my last house.

I didn't bother with trying to tune to the ultrasonic horn I had. I drove the secondary of a toroidal mains transformer using a low voltage drive at ~41KHz and used the primary straight across the piezo horn. Maybe not the most efficient, but it worked effectively and gave quite a nip when touched. What surprised me most was the frequency response of a 6.0.6-240VAC cheapo toroid was at such a frequency. It solved my cat problem BTW with me having to suffer the loud click when the device first powered the horn. I could have resolved this with a bit of signal/startup logic but never bothered in the end.